Add well objects to distributable digital |
Bug fix crash while plotting well objects. |
NoiseMgr - Fix crash generating depth log. |
Support Neuralog NT1000 printer. See printing help for more details. |
Add offset cal term to multipoint cal reports |
Updates for capturing shooting panel statistics during perforating |
DBUtils - Verify name change, check for invalid characters. |
ASFS (generic/Unifire) brownout detection
SRS BRT scriptable arm/fire timeouts |
Unifire - Can import one stage at a time. |
Rock Faithwell addressable switch - monitor update improvements |
Fix spiking issue for WMIDS Zs outputs |
Datapush - Now runs from WExport.exe. Added ability to reduce data output and monitor progress. See Datapush.chm in Warrior\bin for more details. |
Control Panel: New Supplemental tab for extra shortcuts. |
Unifire: Fix for missing xyplot volt,curr,time values.
Use embedded format for big xy plot. Diagnostic report - don't kick off email, just browse to folder. Fix for mouse over popups. |
Initial support for U232 script command - User defined RS232 telemetry |
Add polarity to perforating report events |
Unifire: Added Report->Shot Log Images. Save all shot log images to Warrior\Data\Images folder. |
TCP Server - fix hang on startup |
Fix CCL Filter frequency setting for CSAA panel |
Updates for open line detection control/support PS800W power supply |
Unifire: Gun that has been shot but still is in inventory will have gun number in yellow circle.
More detailed warning dialog with missing or unexpected inventory. Right click in gun diagram for help legend. More descriptions in gun tool tips. |
Plot: Auto size font for scales to fit. |
Support for Perfstrike OR addressable switch |
Antares PDN Tool: Ask user before deactivating gen.; fixed filter interval resetting between passes. |
ELOG tool support for new ISOR panel |
Elog tool with completely new processing. |
WizImport2 - More checks to get the sample rate correctly. |
Unifire: Add more shot details [ V mA mS F deg ] to xyplot.
Add elgs to diagnostic report. Add _service_ to diagnostic report. |
Fix for potential race condition in VAC driven firing/fired events used for system reporting |
Events for changes in shooting panel safety switch position |
Correct CCL load resistor path (for active CCL) |
Improvements for Robertson Geologging downlink/uplink - allow response times down to 100uS |
Correct issues reported for storing SHVOLT and SHCURR calibrations in hardware where applicable |
Revised logic for loading calibration data stored in smart shooting panels |
Improvements to shot log reporting |
Option to override uplink baud rate for Robertson Geologging tools |
Unifire - Updates for gap detection.
Remove hard coded run number from pass name. Pass1-1 becomes Pass1. |
RTCalc - Can add any variable to formula that is described in vars.ini. |
Warrior Backup - add ability to restore files in use. Backup Restore will notify if a reboot is required to finish the file copy. |
ASCTEL, SERMON, PS800W warnings show over Unifire |
XYPlot: Two icons are unique to the toolbar.
The Save button will combine (File->Save Format) and (File->Embed). Now you can move the legend and annotations around, click the Save icon, and those positions will be restored the next time you view that plot. Also any new plots created with that format will use those annotation and legend positions for their initial placement. The Camera button will save the image as a jpg. The file name and directory will be automatic based on the original database name and location. Path=[Database Path]\Images\[Database Name]\[Pass Name].jpg When created, the jpg name will show up in the status bar. |
Warrior Gauge: New Angular options - show half needle and shade trace behind needle. |
Unifire: Show depth of stage in consumption report. Add release notes to consumption report. |
Control Panel - Add button to show patch details. |
XYPlot - Legend and Annotation updates. Save icon will save legend/annotation positions in current plot and will update active xpt to apply positions in any new plots. |
Add calibrations for WMIDS temperature curves and transmitter power control to the user interface |
Warrior Backup: New features will show patch version in Control Panel and patch updates in Release Notes. History button on Restore tab to view changed files since release. |
Sitan WVF vertical scale changed to +/- 2.5v |
Additional calibration report options for multifinger caliper - tolerance checks for calibration offset, linear fit gain and offset |
Optional calibration offset tolerance check/report for caliper arms |
Unifire: Add more shot log details to event log from perf log stat message.
Add consumption report to diagnostic report zip. Stagewizard - fix refresh of stage list when entering stop depths. |
Report perforating power stats honoring polarity |
Support for BlackFrac addressable switches |
Unifire: Enhance gap switch detection. Detect gaps in switch inventory, gray out missing items. |
Perf Job Plan enhancements for building longer guns with multiple intervals. |
New WizImport2.exe - supports array type data from LAS3 and CSV. |
IPlot - Annotation updates: Set button image to match annot orientation.
Save/Restore annotation orientation. Right click annotation tool button for menu. |
ASCII Import: Beta available for importing LAS3 and CSV. Contact SDS for details. |
Warrior Gauge: Make sure gauge size/position are restored on desktop properly. Don't show units with values on List type gauge. |
Unifire - add option to add shot annotation to depth pass. Text annotation will show gun name and CCL depth. |
Service Editor: If GaugeX is deleted, renumber the rest of the gauges. |
Event Log Viewer: Keep track of selected item when filter applied, scroll to that item when filter cleared. Add horizontal scroll bar for long event text. |
Warrior Companion keys now support "Internet Import" functionality - utilizing the Warrior to Warrior direct database transmission utilities |
Correct status channel reporting for Robertson Geolog comms through Warrior surface panel |
Electric log panel support reverted to legacy panels only |
IPlot: Fix edit log curve interpolation for high sample rates. Interpolation was skipping over data. |
Databases that have had an attempted automatic fix will now be made read-only once attempts have been made. |
Control Fire brown out support, 0x00 address enable and UniFire update improvements |
Addressable Switches PostInvSleepmS setting (universal) to delay re-enable of Inventory/Arm buttons in UniFire |
HoistDisplay: Don't save/restore hoist position if minimized. |
Format editor: Bug fix huge numbers for scales, was truncating at 10 digits. Enable wrap mode for curve list type. |
Control Fire - Support 0x00 ID and enhanced brownout detection/notification to UniFire |
XYPlot - Add Portrait / Landscape option default plot presentation. |
Optional tolerance checks for XY caliper verifications |
Unifire: Fix for stop depth not refreshing. Updates to enhanced message box functions to show up on top of Unifire window. |
DNOISE update to support GDT DNST multi-channel tool |
FDP update to support Before/After Surveys with Spartek tools |
Warrior software no longer supports Windows 7.
Enhanced disk free space check while logging. |
RTCalc - new formulas added to build arrays. See servedit help for more details. |
Added support for new Spartek nozzle flow meters (12 pulses/rev) |
Unifire updates:
Import Stages from CSV - example csv installed in Warrior\Manual folder. Enhanced Display - just rounds the corners of buttons for now. Report -> Diagnostic - diagnostic zip to gather up data for client support. Toolbar -> Edit Stage - only one button for stage wizard. Stage Wizard - Toolbar for Save, Add, Delete stage. |
Support for Probe Addressable switches |
Scripted Frames Generic Manchester Encoding telemetry support |
Caliper Correction: Added corrected radii based min, max and average outputs. |
Warrior software no longer supports Windows 7.
Device support for Warrior embedded depth interface |
Preliminary Data Push mode for high definition data streaming |
Services Editor enhancements.
Added user defined real time calculations/outputs. See Help from Service Editor for details. |
Allow perforating service correlate mode to power with shooting panel in ARM position when hardware permits |
Perf Job Planner - POS/NEG perforating fix. |
Unifire - Bug fix abort when saving layout. |
Support 14 arm Gowel caliper tool |
CWH Fluid ID output available for std 3pt cal type |
Warrior software no longer tested with Windows 7.
Support for Hunting Titan ControlFire addressable switches |
Support for Owen GoFire2 addressable switches |
Warnings for Guardian VPM (switch modules) when powering off or switching unsafely |
Support for Rock E-Select addressable switches |
Support for SDS Combined Cased Hole Tool Panel / Shooting Panel |
Warrior Export: LAS, LAS3, CSV - add option for date time format as numeric. |
Unifire - New option to enable tab control for Inventory/Arm/Fire. Button with focus can operate with space bar. Completed Inventory will set focus to Arm, then successful Arm will set focus to Fire, etc. |
XYPlot: Add right click quick look. Autoscale honor current scale ascent/descent. |
Speed up pdf/tiff printing. |
Please note: Due to Microsoft product lifecycles, any future enhancements or patches may not install on operating systems prior to Windows 10.
Automatically created shot logs (hi-res time-based data) for all perforating |
Break Acquisition service menu into columns |
Titan NG telemetry Version 3 support |
Baumer device support added to Asctel |
Waveform display – Bugfix glitch when moving ganged gates |
Borehole image display and plot supports more types such as sector maps. See app help for more details. |
LISToWar - Bugfix lost units |
Unifire -
No Persist plug can have stop depths also Reset Correlate/Perf Mode switch to Perf Mode when service is loaded XY plot bugfix - was not always showing proper annotations |
Services Editor - Back up and restore Gate settings with service |
Interactive Plot bugfix for auto annotations |
IMG - bugfix stall in recalculation |
TVD report bugfix for presenting multiple pages |
Grid editor - simplify editing of grids and tracks using insert and delete keys |
Monitor drop-outs in USB traffic with DSP, warn in event log when over 1 second passes |
Support ISI-100 Rev 2 addressable switch frame/commands |
Fast TVOLT/TCURR session update in use during perforating with addressable switches. Options to monitor deltas to look for wiring/short issues |
Services Editor - Backup / restore multiple presentations for service |
Unifire - Add shortcut for Heading Editor, Banner Editor and Plot Job Editor. Support redundant switches. XY Format and stage minimum distance options. Use Acquisition Numerics refresh rate for all Unifire gauges except Depth. Unifire Depth use Unifire->DepthRefreshRate from wproperties ( default 100ms ) |
Dual (redundant) addressable switch ID's supported |
Add wproperties setting for directional survey import.
[TVD] MeasuredColumn=1 InclinationColumn=2 AzimuthColumn=3 Add csv file option for survey import. |
Support for SWM PerfStrike addressable switches
Updates for Electric Log |
Tool string editor - Variable length tools will allow you to edit the weight. |
SRS addressable switch combinable with correlation telemetries on same polarity |
Add file version check for restoring dsp *.out files. |
Speed up import/export in Services Editor. |
Add Temporary / Permanent option for saving filter changes from Acquisition. |
GDT-EMTA: missing monitor dialog re-added. |
Probe V2 telemetry multi-frame handling fix |
Allow correlation curve scales to be edited. |
Tools editor - can edit multiple sensor offsets and filters at a time. Right click -> Edit Selected. |
Perforating modules - add date to Note on XY Plot. |
Bug Fix - correct "oval" calculation in IMG tool module, was using incorrect pairs of diameters. |
Titan EMT-24: Added Titan specific license check, and added ability to filter curves. |
Unifire - Added optional items: top and bottom jar, bottom release, and safety switch positions. |
Format Editor: Update for individual array elements, user can enter base color, offset, color for every nth curve. |
Fix for plotting individual array elements - plot was not indexing properly into array. |
JobPlan and Stage Manager: Inventory after fire was warning user that gun was still there but did not mark the gun as not fired. Added extra warning message to notify user when that happens. |
Event log viewer - when saving as CSV make sure file has csv extension. |
Fixes for correlation curves Correlation mode. When using multiple presentations, the correlation curve will refer to the first (tab) presentation. |
Img module (mullti-finger caliper processing) will used centered data in downhole calibrations. If using CalibEccCorr for master calibrations then that will be honored for verifications also. |
Service with excluded tools was showing wrong sensor offsets in the tool string drawing when the break tool on option was selected. |
Driver-only reinstall now available through Add/Remove Programs – Modify option. (Can sometimes avoid a complete reinstall after a Windows Update.) |
A Well Sketch will be taken from anywhere in the well information if a sketch for a specific run is not found. |
Interactive plot: remove tabbed presentation with right click on tab -> Delete presentation. |
Event log viewer enhancements |
Plot and export individual array elements |
Shooting panel PSPM R3 (pt10) support for override current limit and trip logging while in telemetry mode |
Unifire - UI improvements. |
Device driver update for CyShPnl |
General support for Weatherford MSC caliper tool |
Log heading format - new type for n required digits editNUM[x]. Heading won't save without entering value for that item. |
Warrior Export - Some of the heading items could get left out of the LAS2/LAS3 export. |
UniFire - Universal Perforating Interface (Stage)
Data Export - fix issue with long file names for export template. |
Fix plot window placement when recalculating gains and offsets for bond log. |
Legal disclaimer moved to Control Panel. |
"Permanent" edited TVOLT and TCURR calibrations will be stored to hardware when capable (not in recalc). |
Spartek support for IMG tool module |
Initial support for Spartek/SDSTEL |
Added install of FTDI CDM Drivers to main installation. |
Tools editor - if calibration type changed, tell user calibrations will be deleted |
Support for EDCP depth panel - two depth meters. |
WExport - fix command line arguments. |
Tools Editor - If calibration type changed, tell user that calibrations will be deleted. |
Iplot can show quick pick of R* curvelist. |
Fixed Caliper correction cross-section image and potato plot, which were coming out with zeroes under some conditions. |
Support for customer supplied casing collar detection module |
Tool string editor - compensate for scroll when placing overbody tools. |
User settings for NOFIRE detect (in STD tool) |
Fix merge wizard bug - similarly named passes merged with wizard may not work i.e. f/w/r/main and f/w/r/main2. |
Addresses known issues with 1903 Windows 10 release/update |
Support for LIM Logging 6 channel telemetry and DIL sonde |
Support for USB44R8 with device temperature reading |
Bug Fix, Usr tool module store/retrieve AdHoc Verifier references |
Fix missing menu in Digital Distributable. |
Generic Addressable Switch Interface for multiple switch types (Tru-Perf, Geodynamics, ISI, SRS) |
DLIS import |
Support for new DTLS with PAX meters. Fix Depth Control Setup - could get hung up while changing tabs in Control Panel. |
Support for Integrated Solutions Inc Addressable Switch |
Updates for Perf Job Plan, Stage Manager: New stage must be above previous. BRT has zero length, use BRT from service to change diagram. Show all shot attempts in shot log shortcut menu. Add Integrated Solutions fire type. |
Various fixes related to Interactive Plot multiple presentations - Annotation editor, Plot Job editor, Merge, Pipe Tally. |
Interactive Plot - multiple presentations.
New Perforating Stage Manager for stage perforating.
DLIS and LAS3 export.
IMG tool module optional multi-finger eccentricity correction method has been improved and now has ellipticity correction. |
Job Plan updates.
Shot At Depth latched when ShotFiring instead of ShotFired. |
New Perforating Stage Manager for stage perforating. |
Interactive Plot - Added multiple presentations. Each presentation in a separate tab. Multiple presentations can be set up per service. The multiple presentations will be saved with the log pass to be restored for future plots and will be listed in the plot job editor to select from. |
Added DLIS and LAS3 export. |
Ganged control of pipe (amplitude) gates and travel time thresholds for radial sectors of bond tools using the waveform monitor |
Img tool module - option to allow and correct for eccentered calibration fixture. New charts available for calibration reports. |
Support for Guardian Global Technologies VPM module |
Updates for Guardian ART2-U tool support |
Support for ANASW R18 (Auto Detect, more HWFilter options) |
Update for Guardian switches. |
Shooting Voltage/Current calibrations are automatically stored and retrieved for panels that have memory capability. |
Fix LAS output while recording - stop index was not updating properly when output was cancelled. |
Latest update of Windows Defender on Windows 10 (update 1803) may block the hardlock runtime service. Steps to fix the issue:
1) From the Start menu, type Windows Defender Security Center. 2) Select App & browser control. 3) Scroll down and select 'Exploit protection settings'. 4) Select 'Program settings'. 5) Select Add program to customize.Choose Add by program name. 6) Type in hasplms.exe. From the Program settings that pops up, set ASLR to OFF, and set DEP to ON. 7) Reboot. Please contact SDS if you have any issues. |
Regretfully, Windows XP can no longer be supported by Warrior. |
Enhancements to speed up XY Plot. |
Job Plan - safety enhancements and high-resolution shot plot with or without log recording. |
Fix job plan inventory requirement for non-addressable tools |
Fix Geolog CHAT tool calibration application when default not needed |
Support for Geodynamics WRT tool and Perforating switches |
Support for Codemeter/WIBU security
Curve lists with offsets could push curves outside of assigned track. |
Support for Guardian Global Technologies AFS addressable switches |
Reducing db storage requirements when running ASFS or TruPerf addressable switches |
Shooting Panel supporting new types including SHF1I that can combine positive or negative telemetry power and has current limiting capability |
Perf Job Planner - Addressable switch activate interval is locked out until switch count matches anticipated count in job plan. |
"correlation mode" support for Simple Reliable Systems addressable switches |
Added support for Global Downhole Tools' EMT-R tool. |
Support Simple Reliable Systems addressable switch and ballistic release technology |
Updates to support shooting panel with telemetry power combine and current limiting hardware. |
Support for "on the fly" perforating with the Probe and Titan shooting panels. (Option to sustain the "enabled" state while at safe depth and saftey key in "Arm" position). |
Gauge library will not crash when data values are not well behaved numbers. |
DBUtils now calculates free disk space correctly when packing a DB after deleting data. |
ASCTEL device module update (delim= specifier) |
IMG tool module now shows raw arm counts in calibration sampling window (previously count up of time)
Support for Probe 24 arm tool |
Support for Titan Motorized Ballistic Freepoint Tool |
Added shortcut for CSV (comma separated value) export to Database Utilities. Can export array data readable by Excel without the limitations of the ODBC exporter. |
Global Build
Tools Editor - Change Backup/Restore to use same tree as main dialog. Select model/serial from tree instead of from two list boxes. |
New DHTen tool module - multiple calibration types, option for "Probe Inc." correction. |
IMG tool module allows specified user cal reports with new terms available for tolerance flagging (ref vs reading, linearity). |
Windows 10 Anniversary Update compatibility
Support for Spartek HTHP toolstring |
Installer will register 'wbu' file extension so double click will open Warrior Backup, Tools Editor, or Services Editor. |
Added separate switch for color map units and range from format editor. VDL log insert can now have both the horizontal units/range and the output units/range where the output units/range is shown on top of the color map. |
SDSUSB driver install for Warrior 8 is no longer backwards compatible with Warrior 7. To use both Warrior 7 and Warrior 8, install Warrior 7 after installing Warrior 8, or contact SDS for more assistance. |
Rework color map log inserts. For the Image 3D type, the Units and Range should go with the color map only. The Label check box will show the Label, the Show color map option will show the color map strip, and the Range will go with the color map. The color map name should not be in the log insert at all. Potato plot will show the label only. VDL will show the horizontal unit. |
Can export LIS in units per Warrior Control Panel data unit selection. |
Services Editor - When service exists during import, offer to import with different name. |
Tools Editor - Change so user exports and imports one tool group at a time ( Logging, Accessory, TCP ). |
Fix LIS import for time logs. |
Support units translation for VDL data. |
Enhancements and bugfixes
Fix Image3D shift in plot. |
Enhancements and bugfixes
Bug fix signature and vdl error when plotting less than the entire range of data. |
Depth persistence between service changes when using SDS hardware for depth tracking, users may want to disable appropriate warning in Control Panel |
Support for Global Downhole Tools EMDS |
Add Pure monochrome mode toggle via Control Panel - Plot tab. Makes a sharper font for direct monochrome plots. |
Bug Fix. Calibration retrieval for muliple tool instances. |
Global Build
Initial support for GPS devices such as Garmin that use NMEA messages and omit time synchronized pulse triggers |
Initial support for Global Downhole Tools Noise and Accoustic Fluid Density Tools |
Signature - Center or Minimum baseline option added. Sonic data should the Center option (original method). Use new Minimum option for spectra.
VDL - Apply max value to vdl dither if more data points than pixels. |
Add following to logsys.ini to create alias for sensor names in tool diagram:
[ToolDiagramAliasNames] Sensor=Alias |
Global Build
Hardlock Driver Version 7.4.1 |
Auxilliary Power Supply support updates for TPAO and PICO type usage |
Fractal PSAS support |
Small correction to quick-look ECCE output from IMG tool module |
Borehole corrected outputs for RSN and RLN resistivities based on borehole diameter and mud resistivity |
Mathpack - Add ability to calculate live passes. |
Tool support added for Scientific Drilling TFD (Fluid Density) |
Support for Impact Selector Merlin |
Support for Thermochem SRO |
Countdown Timer for C&J addressable switches in ARM and FIRE settings. Correlation mode for GR-Perf now supported without need of changing services |
Fix for undersampled HWS memory data. (Bad CCL) |
Support for PICO SGR, Neutron |
Support for Signum Instruments Tools - IFC, IDL, IAI, IWS, ITP |
Fix multifinger caliper verification report issue (0 or random values in calibration report). |
Accept underscores as valid characters in variable names for Mathpack formulas. |
Not reading color map from pplot embedded presentation. |
Support for OPMR panel including Hall Effect Sensor control |
Initial diagnostic support for ASFS-HT and Secure-2 switches |
Fix LIS Details tab display - was not showing correct output sample rate for each item. Fix LAS export from DBUtils - Format was starting up as CSV instead of LAS. |
Plot screen preview not always in color |
Removed File menu, and added New and SaveAs options to the 'Grid Layout menu. |
Probe Lithodensity RHOB output updates (chi-squared substituted for Hanning) |
Fix memory allocation error when deleting or overwriting a service and services.ini has a long list of services. |
Fix the issue hampering recalc of data passes with Titan Shooting panel raw data. |
Global Build 2015 Release
Fixed bug that could cause incorrect tracer ejetor/detector spacing calculation |
Support for TELAH_R5 board added |
Fix Spartek Err Count display |
Borehole imaging rewrite to reduce banding in 3D images. |
Deteq Elog tool relay support bug fix |
LET-H and LET-P independent and automatic control of panel filter settings for correlate/perf mode |
Added support for Hunter Well Science Multifinger Caliper tools |
Spartek Accoustic Density with RTD support |
Fix bug in FDP tool module software that was inhibiting user from making multipoint calibrations |
Spartek SRO tool/telemetry support updated for used initiated tool configuration |
For tools with multiple instances, all available serial numbers were not always shown in tool string editor. |
Titan telemetry enhanced validation of Gowell embedded frames |
Hotwell/Wellsun updates for RBT data transform |
Inclinometor tool software now has optional filters for computed outputs such as deviation |
Enhanced support for Benchmark AMS panels: 9600 or 38400 baud; panel depth now changes with Warrior. |
Fix LAS and CSV 'Cancel at current depth' option when exporting live dataset - stop depth was not getting calculated correctly. |
Fix bug sometimes preventing generation of composite logs or drag run profiles when multiple shot tables exist in the same run. |
Fix bug causing depth errors when depth-shifted data is recalculated or extracted. |
Add option to FlowVelocity for injection well calculations. |
ASCTEL bug fix correcting the "Kerr" communication options |
Fix hot var scroll setting. Increase size of hot var dialog. |
Prestemp tool module software will cater to temperature outputs based on the QD pressure type algorithm. |
AuxPS device (Auxialliary power) support for SDS version 2 board (OPAQ) controlling PS1 for caliper motoring |
Gowell Caliper mtc files now have optional terms that can override defaults for DEVI output calculation |
Correct the 3 axis inclination calculation in INCL software |
Can copy a tool to a new name from tools editor. |
Add option to setup screen for automatic file naming.
When exporting a live pass, another button will show up that will enable the user to cancel the export at the current log depth. |
Schlumberger ASFS identifying Julia and Eclipse switches for query options as well as specific firing messages. Added audible beep for ECLIPSE while firing for a six second (minimum needed to ensure correct operation). |
Inclinometer tool module has new calibration type option (inclined calibration points with vertical reference). Additionally there is an optional RB Offset calibration to correct for RB reading with a reference point (caliper finger 1 for example). |
Query of "Julia" addressable switches supported |
Allow to edit API code for DEPTH,TIME for LAS export. |
Fix 'Blue View Compatible' tiff creation for 32bit versions. |
Support for new CBL1 R10 Filter board |
Support for new Hotwell radial bond, multifinger caliper, and production logging tools |
Model Specific option for Tel ID added to FDP, CWH and CFB modules |
When restoring a configuration from Warrior 7, each service and tool will be restored individually. |
Sentinel HASP version 6.62 driver update - Fix for 'Driver Version mismatch' error. |
C&J addressable switch updates to cater for short condition |
Well objects - no limit to number of depth intervals per object. Save last object ratio to be used as default for next time. |
Enabled vertical annotations from annotation editor. |
CSV template could include a signature curve that would break an LAS export. |
Add zoned scale changes for digital distributable. |
Fix for Signature and VDL plots - plots with nonzero offset not calculated correctly. |
Fix for extra long tiff files on 32bit installs. |
Fix CYSDA surface data acquistion module sample recording issue |
Added multi-line annotations. Annotation editor can accept carriage returns for line breaks within an annotation. Otherwise a long annotation will be wrapped when the text reaches the left or right border. |
Warrior Export - dialog is resizeable. Can clear default sample rate. |
Tool string editor - fix issue with removing/changing serialized accessory tools. |
Added BlueView Compatible option for Tiff LZW from Tiff Setup dialog. If your particular viewer cannot open your tiff file, then try this option. |
Eclipse addressable switch support update, issue of staying locked in Query mode (not reverting to Arm) fixed. |
Global Build
Added support for Pioneer Petrotech PPS71 SRO tool/telemetry support |
GOWell multifinger caliper tool mtc files can have optional relative bearing (RB) offsets declared that will initialize the RB calibration offset used in processing |
New XYPlot. Setup procedure is slightly different. See Help from XYPlot for more details |
Pdf and tiff now have separate horizontal and vertical resolutions. If you don’t edit anything then the resolutions are equal as they were before the change was made. For example, the Printrex 920 resolution is 300x200, so to make an image compatible with that printer it would need to have similar resolutions. |
Updates for Probe (PTX) scripted telemetry for 32 bit channels, masking available |
Updated support for Titan NextGen telemetry to have user scripted commands available from the device monitor |
Correct PLL multiplier options for PIP panel |
ECLIPSE addressable switches now recognized during perforating services |
24 bit channel support for Probe scripted telemetry |
From Format Editor -> Layout : Can edit custom layout/grid for current format or all layouts. Made two separate menu items to clarify what layout is being edited. |
For ASFS, set all gun addresses to -1 after fire detected to force user to inventory gun before perforating next interval. |
Bug fix to conversion factors for variable units of flow measurements (vuFLOW). Conversion between BPD, BPM, M3D were scaled incorrectly |
Bypass rate output, calculation based on WHFLOW1 (pumping pressure), LSPD (cable speed), Casing OD and Casing thickness |
Warrior gauge updates: Numeric gauge will now honor the background color, so some gauges may start up with a white background that were gray before. Use the gauge properties to set the background color. You can now select the font size in addition to the font style and override the number of characters to determine the font size. You can set a default font for all gauges from the Warrior Control Panel -> Acquisition tab. |
Added option to multiarm IMG module for displaying image to scale. With this option, image 3D and potato plots will change size as different sized casing are logged rather than auto-scaling the image. |
Global Build
Database Utilities - resizeable dialogs for Alias, Differential, Correlation Curves, Depth Shift, Automerge, Rename. |
Mathpack - fix time log outputs. |
XY Caliper: CALA (Average Caliper) logged range is now correct; the system hang-up at the end of a recaclulation has been corrected. |
SDSTEL support for memory frame definitions |
Database select dialog now resizeable for longer database/dataset names. |
Remove watermark from pdf documents. |
Resizeable database select dialogs - handle long names better. |
SP Process option added to DELOG tool module. The default is "No", the tool configuration should now add the SP software module and service configuration be updated with "spoffset" and "spcalibrate" in the SDSTIP options for extra funcionality |
Tracer detectors option for output units (GAPI, cps or None) |
Support for new Deteq ELOG tool with directional data |
Fixes for the SIMPLEC RAG service (uses monocable option) |
Updated WAMNCH telemetry services to offer downlink slider |
Updated Katwell telemetry monitor to control switchable uplink baud rate |
Sentinel HASP version 6.56 for Windows 8 support. |
Fix error message during Autobackup. |
Fix issues with Spartek PLtelemetry utilizing 16 sensor channels and self identifying centralizers |
Add CSV (Comma Separated Value) export option to Warrior Export program. |
PXD Boot Loader enhancements |
Control Panel External Power Supply type selection (for appropriate hardware) added to Acquisition Configuration |
Spectral Gamma Ray tool software using new monitor, supporting preliminary AlphaNeutronics tool type. Raw window count outputs now available (specific tool types) |
Support for KatWell Magnetic Thickness Tool |
Support for Permaworks PTS01 modified telemetry frame |
Support for Titan Compensated Neutron (4ATM) |
Enhancement to allow serial port sharing between devices such as ASCTEL and SERMON |
Added support for Kuster PT tool telemetry frame |
JPT/GOWell TSGT telemetry updates for sequential frame index checking/reporting |
Fix ability to add live pass to plot job. To cancel a live hardcopy from Interactive Plot, select File -> 'Abort the current log plot' from Presentation Plot. |
Titan "Next Gen" user configurable telemetry initial support (tested with 8 sector bond tool, GR-CCL, GOWell 40 arm caliper) |
USR tool module software updated for optional Verification Survey References and Master Verification without Master Calibration |
Fix issue with Probe OH Compensated Neutron missing calibration terms from report. |
Update Probe Hi-res Dual Laterolog to include before/after verifications |
Multifinger Caliper raw sensor readings (non temperature corrected) available for calibration reports. |
Applied Freepoint Tool, external power supply support. |
Format Editor has simple interface for lists of curves (for example, R1, R2, R3, ... R40 now via R*). |
Kuster Telemetry Monitor to more easily visualize tool synchronization. |
Updated Warrior USB device drivers (Cypress 3.04.0007.0000) |
Slider gain control available for digital CCL signals, configured in the tool module setup. |
Katwell Telemetry support for multifinger caliper tools, magnetic thickness tools, gyro tool, GR-Temp tool. |
ACE 1000 Telemetry support for Open Hole logging tools. |
Add selectable unit for porosity - decimal or percentage. |
Hunter Well Service PFMT Telemetry support. High Temp Production Logging. |
The Warrior 8 release includes many new features incuding support for Unicode, unlimited database size, and 64bit capabilities.
Other new features include:
* Requires separate license Warrior 8 databases cannot be read by previous versions of Warrior, but Warrior 8 can read older databases. |
Windows XP:
The minimum operating system supported is Windows XP Service Pack 2. Known issues on Windows XP: Microsoft has updated the list of third-party certification authorities that are trusted by Windows but on Windows XP this update is not installed automatically. The user must download and install the update package (see http://support.microsoft.com/kb/931125). Without this update, Warrior programs may give an 0x800b010a error when starting as the system is unable to verify the digital signature of certain system files. Alternatively, the user can install the two intermediate certificates (primary and secondary) which are found in the Warrior Bin folder. These give an alternative path back to a trusted root certificate. |
Multifinger caliper:
Removed presentation options for 'Make window bigger' and 'Bulge factor'. Warrior 7 plots will match Warrior 8 plots by setting both of those parameters to 0 in Warrior 7. |